CDLK Series Immersible Multistage Pump

Product Overview

Category: Centrifugal Pumps

CDLK Series Immersible Multistage Pump. Designed for water supply, circulation, HVAC, boosting and general industrial liquid transfer. Contact Shenyin Pump for duty-point review, materials and configuration options.

  • Duty-point review and pump selection support
  • Outline drawings and installation instructions available

Export inquiry support

Need help selecting CDLK Series Immersible Multistage Pump?

Send flow, head, medium, temperature, voltage/frequency, quantity and destination country. Our engineering team can review duty point, materials, seal type and configuration for OEM, EPC and export projects.

Technical Information

The information below is for reference. Final order data is subject to the technical agreement and product nameplate.

I. Applications

CDLK/CDLKF pumps are designed for conveying machine tool coolants and lubricants, condensate, and fluids in industrial cleaning equipment and other immersion-pump applications. They accommodate various temperature, flow, and pressure ranges; CDLK is suitable for non-corrosive liquids, while CDLKF is suitable for mildly corrosive liquids. Specific applications include EDM machines, lathes, grinders, machining centers, cooling units, industrial cleaning equipment, and filtration systems.

II. Operating Conditions

Thin, clean, non-explosive liquids free of solid particles and fibers; suitable for conveying water, aqueous cooling solutions, and cutting lubricants.

Liquid temperature: Standard version -15°C to +70°C; Hot water version +70°C to +120°C.

III. Pump

CDLK/CDLKF pumps are non-self-priming multistage centrifugal pumps equipped with standard electric motors. The motor shaft connects directly to the pump shaft via a coupling through the pump head. Pumps can be fitted with an optional intelligent protector to provide effective protection against dry running, phase loss, and overload. To meet specific installation depth requirements for tanks or containers, empty chambers can be installed to adjust the pump length; please refer to the dimensions/weight tables and product range tables for lengths corresponding to different stage counts.

IV. Motor

Totally enclosed, fan-cooled, 2-pole standard motor.

Enclosure class: IP55

Insulation class: F

Standard voltages:

50Hz:

1×220-230/240V

3×200/346V

3×220-240/380-415V

3×220-225/380-440V

60Hz:

3×200-230/346-400V

3×220-255/380-440V

3×220-277/380-480V

Motors with other voltages are available upon request.

Single-phase motors available in the 0.37–2.2 kW range. V. Maximum Ambient Temperature:

When the pump operates at an ambient temperature above 40°C or an altitude exceeding 1,000m, the motor output power (P2) will decrease due to reduced air density and poorer cooling efficiency. A motor with a higher power rating is required for operation under these conditions.

VI. Liquid Temperature

Standard temperature type: -15°C to +70°C

Hot water type: +70°C to +110°C

Model Designation

CDLKF 4-120/12

CDLKF412012-/
12

Number of impeller stages

120

Stage number × 10

4

Rated flow rate (m³/h)

F

Wetted parts material is stainless steel 304 or 316

CDLK

Immersion multistage centrifugal pump

Note: The CDLK immersion multistage centrifugal pump adopts a vertical multistage structure with the pump section immersed in liquid during operation. It features compact footprint, stable operation, low noise, high head, and convenient maintenance. It is widely used in machine tool cooling systems, industrial cleaning equipment, filtration circulation systems, and industrial liquid transfer applications.